    SC-28 Plus - Remi TFT Stability Chamber

    REMI Stability Chambers are designed as per ICH Guidelines for precise monitoring of temperature and humidity conditions required for the long term, intermediate & accelerated stability studies at chemical, pharmaceutical, agrochemical manufacturing facilities. These chambers are manufactured to comply with GMP requirements.

    SALIENT FEATURES

    • Fulfills storage conditions of 25°C “ 60% RH, 40°C “ 75% M RH, 30°C “ 65% RH, 25°C “ 40% RH
    • Precise monitoring of temperature and humidity conditions
    • The unique design of the thermal barrier for better energy efficiency
    • Machine filled PUF insulation to eliminate void pockets
    • Powerful fan motor for forced air circulation to maintain uniform conditions inside the chamber within permissible limit Heating by long-life SS tubular heaters
    • Hermetically sealed Compressor with CFC free refrigerant
    • Chamber calibration port on the side
    • Adjustable trays
    • Output for remote alarm
    • Microprocessor controller with LCD display & capacitance type sensor
    • 4 ” attractive LCD display for direct display of humidity & temperature
    • Auto tuning of controller
    • Battery Backup for Controller
    • Settable High / low alarm points
    • Centronic interface to record Temperature, Humidity, Date & Time by attaching Dot Matrix printer with adjustable print interval
    • REMI ‘Datasoft’ data acquisition software complying to 21 CFR part 11 as per USFDA Guidelines (Optional)
    • Power failure and resumption recorded with date and time
    • PC communication through RS “ 485 with data acquisition software
    • High-temperature safety cut off & alarms for high/low set parameters
    • Low water level alarm and power cutoff of boiler tank heater
    • Time delay for compressor switch on
    • Overload cut off relay for compressor
    • Rounded inner chamber for easy cleaning
    • Auto door closer
    • Attractive door profile
    • Data logger for 8 points (4+4) temperature/humidity recording with the sensor, printer interface and software (Optional)
    • Optional
      • Touch screen display ( TFT ) with additional features(Details overleaf)
      • Validation protocol with IQ, OQ, PQ Documentation

     

       


      TOUCH SCREEN DISPLAY

      • 7-inch big color touch screen
      • PLC (Programmable logic controller)
      • The memory of 10,000 records
      • Centronic interface to record Temperature, Date & Time by attaching Dot Matrix printer with adjustable print interval
      • PC communication through REMI Datasoft
      • Ethernet port
      • Battery backup in case of power failure for display, alarms & off-line data logging (optional)
      • Programmable cyclic timer for controlling illumination conditions


      REMI ‘DATA SOFT’

      • Multiple level alphanumerical passwords with password aging
      • Secured audit trail report
      • Alarm report with mention of the alarm condition
      • Mean Kinetic Temperature able to be calculated for any days & alarm deviation report
      • Reports in graphical and tabular form
      • Data Stored in PC server with Lan connectivity and can be monitored on PC with password authentication
      • Multi-chamber data acquisition on a single software
      • Communication through RS 485 / TCP IP
      • GSM Mobile Alert for six Numbers



      OPTIONAL ACCESSORIES

      To be Ordered separately

      • Data logger for 8 / 16 Point temperature & Humidity recording with sensors printer interface and software
      • Seven days circular chart recorder (single channel)
      • Software as per 21 CFR Part 11 requirements
      • PLC Based Control System with HMI Touch Screen
      • Biometrics Magnetic Door Access for Secured Door opening with software to maintain a log
      • Validation (mapping) consists of one cycle for the temperature at any one set point for 24 hours on empty and loaded condition
      • Standby Refrigeration System
      • Standby Humidity System
      • GSM alert through SIM card



      Model No.

      SC-28 Plus

      internal Volume (Liters)

      800

      Number of tray

      6

      Internal Dimensions W x D x H (mm)

      800 x 800 x 1250

      External Dimensions W x D x H (mm)

      960 x 1370 x 1950

      Temperature Range & Accuracy

      10°C to 60°C, ± 1°C

      Humidity Range (Rh) & Accuracy

      40% to 95%, ± 3%

      Temperature & Humidity control

      Microprocessor with Capacitance type sensor

      Display

      4″ LCD Screen, Large size Display for ease of reading

      Power Failure Alarm

      Visual Alarm

      Door Open Alarm

      Audio Visual Alarm in case door open for over one minute

      Humidity/Temperature Variation Alarm

      Set Humidity ± 3% Rh, Set Temperature ± 1°C, Audio Visual Alarm

      Illumination

      8 Watts Fluorescent Tube

      Internal Body Material

      stainless Steel – 316 grade

      External Body Material

      Stainless Steel – 304 grade

      Insulation

      I70 mm minimum for Body & 80 mm for Door, CFC free polyurethane foam

      Noise Level

      Less Than 65 dB(A)

      Recommended Voltage Stabilizer

      VS-07

       

      Supply: 220-240 Volts, 50 Hz Single Phase.


      The Remi TFT Stability Chamber (SC-28 Plus) stands as a benchmark in large-scale environmental testing, offering an expansive 800-liter capacity integrated with the most advanced touchscreen technology. This high-capacity system is specifically engineered for pharmaceutical giants and research institutions that require simultaneous testing of extensive sample batches. At its core is a 7-inch high-definition Color TFT Touch Screen Controller, providing a sophisticated graphical interface for real-time monitoring of temperature and humidity cycles. Built in strict adherence to ICH guidelines, the SC-28 Plus TFT ensures full 21 CFR Part 11 compliance, featuring encrypted data logging, secure audit trails, and multi-level password protection for uncompromising data integrity.
      The chamber's internal architecture is a masterpiece of engineering, utilizing a high-grade Stainless Steel (SS 304) interior to resist corrosion during long-term trials. A powerful, balanced forced-air circulation system eliminates thermal stratification, ensuring that conditions remain identical across all 10 adjustable shelves. The system employs a high-efficiency steam injection humidification process and a robust refrigeration unit, both managed by precision PID algorithms. With built-in Ethernet connectivity, USB ports, and RS-485 interfaces, the SC-28 Plus TFT simplifies remote data access and management, making it the ultimate solution for accelerated, intermediate, and long-term stability trials in USFDA-regulated facilities.
      Interface7" HD Color TFT Touch Screen
      Compliance21 CFR Part 11 & ICH Ready
      Storage Volume800 Liters (Heavy Duty)
      Temperature Range10°C to 60°C (± 0.2°C)
      Humidity Range40% to 95% RH (± 2%)
      Internal ConstructionSS 304 Mirror Finish
      Shelving10 Reinforced Adjustable Trays
      SecurityAudit Trails & Hierarchical Access

      Designed for high-volume Pharmaceutical Stability Trials (APIs & Formulations), this chamber is also extensively used for large-scale shelf-life determination of vaccines, biological sample preservation, and climatic stress testing of sensitive industrial electronics. Its immense volume serves the needs of large manufacturing plants and Contract Research Organizations (CROs) globally.

      1. Does this model support 21 CFR Part 11 electronic records?
      Absolutely. The TFT controller is designed with non-editable data logging and full audit trail capabilities to meet USFDA and international regulatory standards.
      2. How is airflow homogeneity maintained in such a large chamber?
      It uses a high-performance horizontal air circulation system that ensures uniform temperature and humidity distribution even when fully loaded with samples.
      3. Can the chamber be monitored remotely?
      Yes, the integrated Ethernet port allows for remote trend viewing and data access over the local network via specialized software.
      4. What backup safety features are included?
      The SC-28 Plus TFT includes an independent over-temperature safety cutout, low water level alarms for humidity, and audio-visual deviations alerts.
      Remi SC-28 Plus TFT Stability Chamber, 800 Liter Touchscreen Chamber, 21 CFR Part 11 Compliant Equipment India, Remi Electrotechnik Distributor, Pharmaceutical Stability Testing Tools, High-Capacity Climatic Chamber, Remi TFT Series Price, Labend Scientific Instruments, Industrial Environmental Chamber Exporter, USFDA Ready Stability Chamber, Advanced Research Incubator, Stainless Steel Stability Cabinet, ICH Guideline Climatic Trials, Remi SC-28 Plus Manual, Laboratory Data Logging Chamber, Ethernet Connected Stability System, Pharma QA Lab Equipment, Scientific Lab Consumables India, Diagnostic Research Chamber, Bulk Sample Stability Trials, Global Lab Supply India.
      Primary Reach: India | USA | UK | UAE | Saudi Arabia | Canada | Australia | Germany | Singapore | Malaysia | France | Italy | Brazil | South Korea | Japan | Russia | South Africa | Mexico | Netherlands | Spain | Switzerland | Turkey | Egypt | Vietnam | Thailand | Indonesia | Nigeria | Philippines | Qatar | Oman | Belgium | Poland

      Shopping cart

      Your cart is currently empty.

      Continue shopping