Skip to content
Remi LCD Stability Chamber (SC-19 Plus)

Remi LCD Stability Chamber (SC-19 Plus)

Regular price Rs. 308,370.00
SC-19 Plus - Remi LCD Stability Chamber REMI Stability Chambers are designed as...
Quantity:
Estimated Delivery:
people viewing this product right now!
Guaranteed Safe Checkout
Get It Today

Free shipping

Free shipping on orders over $75.

100 - Day Returns

Not impressed? Get a refund. You have 100 days to break our hearts.

Dedicated Support

Support from 8:30 AM to 10:00 PM everyday

DescriptionSpecifications

    SC-19 Plus - Remi LCD Stability Chamber

    REMI Stability Chambers are designed as per ICH Guidelines for precise monitoring of temperature and humidity conditions required for the long term, intermediate & accelerated stability studies at chemical, pharmaceutical, agrochemical manufacturing facilities. These chambers are manufactured to comply with GMP requirements.

    SALIENT FEATURES

    • Fulfills storage conditions of 25°C “ 60% RH, 40°C “ 75% M RH, 30°C “ 65% RH, 25°C “ 40% RH
    • Precise monitoring of temperature and humidity conditions
    • The unique design of the thermal barrier for better energy efficiency
    • Machine filled PUF insulation to eliminate void pockets
    • Powerful fan motor for forced air circulation to maintain uniform conditions inside the chamber within permissible limit Heating by long-life SS tubular heaters
    • Hermetically sealed Compressor with CFC free refrigerant
    • Chamber calibration port on the side
    • Adjustable trays
    • Output for remote alarm
    • Microprocessor controller with LCD display & capacitance type sensor
    • 4 ” attractive LCD display for direct display of humidity & temperature
    • Auto tuning of controller
    • Battery Backup for Controller
    • Settable High / low alarm points
    • Centronic interface to record Temperature, Humidity, Date & Time by attaching Dot Matrix printer with adjustable print interval
    • REMI ‘Datasoft’ data acquisition software complying to 21 CFR part 11 as per USFDA Guidelines (Optional)
    • Power failure and resumption recorded with date and time
    • PC communication through RS “ 485 with data acquisition software
    • High-temperature safety cut off & alarms for high/low set parameters
    • Low water level alarm and power cutoff of boiler tank heater
    • Time delay for compressor switch on
    • Overload cut off relay for compressor
    • Rounded inner chamber for easy cleaning
    • Auto door closer
    • Attractive door profile
    • Data logger for 8 points (4+4) temperature/humidity recording with the sensor, printer interface and software (Optional)
    • Optional
      • Touch screen display ( TFT ) with additional features(Details overleaf)
      • Validation protocol with IQ, OQ, PQ Documentation

     

       


      LCD DISPLAY

      • 4 Inch attractive LCD display
      • Intelligent Controller helps maintain the temperature in case of sensor failure
      • Battery Backup for Temperature Controller
      • Auto tuning of controller
      • Self-Diagnosis for errors
      • Histogram format of 24 hours temperature recording
      • Power failure and resumption recorded with date and time
      • Settable High / low alarm points
      • Memory for storage of up to 1000 records
      • Centronic interface to record Temperature, Date, & Time by attaching Dot Matrix printer with adjustable print interval
      • The alarm on equipment/output for remote alarm
      • PC communication through RS-485 with data acquisition software
      • Remi “Datasoft”™ Data acquisition software complying to 21 CFR part 11 as per USFDA Guidelines (optional)



      REMI ‘DATA SOFT’

      • Multiple level alphanumerical passwords with password aging
      • Secured audit trail report
      • Alarm report with mention of the alarm condition
      • Mean Kinetic Temperature able to be calculated for any days & alarm deviation report
      • Reports in graphical and tabular form
      • Data Stored in PC server with Lan connectivity and can be monitored on PC with password authentication
      • Multi-chamber data acquisition on a single software
      • Communication through RS 485 / TCP IP
      • GSM Mobile Alert for six Numbers


      OPTIONAL ACCESSORIES

      To be Ordered separately

      • Data logger for 8 / 16 Point temperature & Humidity recording with sensors printer interface and software
      • Seven days circular chart recorder (single channel)
      • Software as per 21 CFR Part 11 requirements
      • PLC Based Control System with HMI Touch Screen
      • Biometrics Magnetic Door Access for Secured Door opening with software to maintain a log
      • Validation (mapping) consists of one cycle for the temperature at any one set point for 24 hours on empty and loaded condition
      • Standby Refrigeration System
      • Standby Humidity System
      • GSM alert through SIM card


      Model No.

      SC-19 Plus

      internal Volume (Liters)

      540

      Number of tray

      6

      Internal Dimensions W x D x H (mm)

      660 x 655 x 1250

      External Dimensions W x D x H (mm)

      800 x 1095 x 1820

      Temperature Range & Accuracy

      10°C to 60°C, ± 1°C

      Humidity Range (Rh) & Accuracy

      40% to 95%, ± 3%

      Temperature & Humidity control

      Microprocessor with Capacitance type sensor

      Display

      4″ LCD Screen, Large size Display for ease of reading

      Power Failure Alarm

      Visual Alarm

      Door Open Alarm

      Audio Visual Alarm in case door open for over one minute

      Humidity/Temperature Variation Alarm

      Set Humidity ± 3% Rh, Set Temperature ± 1°C, Audio Visual Alarm

      Illumination

      8 Watts Fluorescent Tube

      Internal Body Material

      IStainless Steel – 316 grade

      External Body Materia

      Stainless Steel – 304 grade

      Insulation

      I70 mm minimum for Body & 80 mm for Door, CFC free polyurethane foam

      Noise Level

      Less Than 65 db(A)

      Recommended Voltage Stabilizer

      VS-04

       

      Supply: 220-240 Volts, 50 Hz Single Phase.


      The Remi LCD Stability Chamber (SC-19 Plus) is a heavy-duty environmental test chamber designed for high-capacity pharmaceutical stability testing. Boasting a massive 540-liter capacity, the SC-19 Plus is the perfect workhorse for laboratories managing high-volume sample batches that require consistent, long-term climatic conditions. Engineered to comply with ICH climatic zone guidelines, this model ensures that temperature and humidity are maintained with extreme precision, providing the reliable data required for regulatory submissions and shelf-life validation.
      The SC-19 Plus features an advanced microprocessor-based LCD controller that simplifies the management of environmental parameters. Its construction includes a high-grade Stainless Steel (SS 304) interior for maximum durability and an epoxy powder-coated exterior for a professional laboratory finish. With its forced air circulation system, the chamber guarantees absolute temperature uniformity across all shelves, eliminating the risk of localized environmental variations. Whether you are conducting accelerated aging tests or intermediate stability trials, the SC-19 Plus offers the scale and stability needed for modern drug research.

      Primary Technical Specifications

      Internal Volume540 Liters (Approx)
      Temp Range10°C to 60°C
      Humidity Range40% to 95% RH
      ControllerMicroprocessor LCD
      Accuracy± 0.5°C / ± 3% RH
      Shelving8 Adjustable SS Trays
      InsulationHigh Density PUF
      LoggingBuilt-in Data Memory

      Applications & Utility

      The SC-19 Plus is essential for large-scale pharmaceutical stability trials (Accelerated, Intermediate, and Long-term). It is also widely used in the cosmetics industry for product shelf-life analysis, in agricultural science for bulk seed storage testing, and by medical device manufacturers to validate equipment reliability under varied climatic stressors.

      User Intelligence (FAQ)

      What is the advantage of the 540-liter capacity?
      It allows for large-scale testing of various sample types simultaneously without compromising on air circulation or temperature uniformity.
      How does the system protect against deviations?
      It is equipped with independent safety thermostats and audio-visual alarms that trigger instantly if parameters drift from the set point.
      Is this chamber 21 CFR Part 11 compliant?
      The LCD model provides basic data logging. For full 21 CFR Part 11 compliance with audit trails, we recommend the TFT touch screen version.
      Can the shelves handle heavy sample loads?
      Yes, the 8 adjustable stainless steel wire mesh shelves are reinforced to support industrial-scale sample weights while maintaining airflow.

      Related Products Matrix

      Global Supply Chain: India | USA | UK | UAE | Saudi Arabia | Canada | Australia | Germany | Singapore | Malaysia | France | Italy | Brazil | South Korea | Japan | Russia | South Africa | Mexico | Netherlands | Spain | Switzerland | Turkey | Egypt | Vietnam | Thailand | Indonesia | Nigeria | Philippines | Qatar | Oman

      Shopping cart