{"product_id":"remi-lcd-chm-19-plus","title":"Remi LCD Humidity Chamber (CHM-19 Plus)","description":"\u003cbody\u003e\n\u003cp\u003eCHM-19 Plus - Remi LCD Humidity Chamber\u003c\/p\u003e\n\u003cdiv class=\"wpb_text_column wpb_content_element  wpb_animate_when_almost_visible wpb_right-to-left wpb_start_animation\"\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003cp\u003eREMI Humidity Chambers are designed for testing of electronic, electrical components, corrosion studies on mechanical parts, shelf-life studies on paints, varnishes, and cement at respective manufacturing facilities. These chambers control precise temperature and Humidity.\u003cbr\u003e\u003cspan\u003eThese chambers are available in standard \u0026amp; GMP versions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wpb_text_column wpb_content_element  wpb_animate_when_almost_visible wpb_right-to-left wpb_start_animation\"\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003ch4\u003eSALIENT FEATURES\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePrecise monitoring of temperature and humidity conditions\u003c\/li\u003e\n\u003cli\u003eTemperature range 10°C to 60°C, Humidity range 40% to 95% RH\u003c\/li\u003e\n\u003cli\u003eThe unique design of the thermal barrier for better energy efficiency\u003c\/li\u003e\n\u003cli\u003eMachine filled PUF insulation to eliminate void pockets\u003c\/li\u003e\n\u003cli\u003ePowerful fan motor for forced air circulation to maintain uniform conditions inside the chamber\u003c\/li\u003e\n\u003cli\u003eHeating by long-life SS tubular heaters\u003c\/li\u003e\n\u003cli\u003eHermetically sealed Compressor with CFC free refrigerant\u003c\/li\u003e\n\u003cli\u003eChamber calibration port on the side\u003c\/li\u003e\n\u003cli\u003eAdjustable trays\u003c\/li\u003e\n\u003cli\u003eOutput for remote alarm\u003c\/li\u003e\n\u003cli\u003eMicroprocessor controller with LCD display \u0026amp; capacitance type sensor\u003c\/li\u003e\n\u003cli\u003e4″ attractive LCD display for direct display of humidity \u0026amp; temperature\u003c\/li\u003e\n\u003cli\u003eAuto tuning of controller\u003c\/li\u003e\n\u003cli\u003eSettable High \/ low alarm points with date and time\u003c\/li\u003e\n\u003cli\u003eCentronic interface to record Temperature, Humidity, Date \u0026amp; Time by attaching Dot Matrix printer with adjustable print interval\u003c\/li\u003e\n\u003cli\u003eRemi “Datasoft”™ data acquisition software as per 21 CFR part 11 requirements (Optional)\u003c\/li\u003e\n\u003cli\u003ePower failure and resumption recorded with date and time\u003c\/li\u003e\n\u003cli\u003ePC communication through RS-485 with data acquisition software\u003c\/li\u003e\n\u003cli\u003eHigh-temperature safety cut off \u0026amp; alarms for high\/lowset parameters\u003c\/li\u003e\n\u003cli\u003eLow water level alarm and power cutoff of boiler tank heater\u003c\/li\u003e\n\u003cli\u003eOverload cut off relay for compressor\u003c\/li\u003e\n\u003cli\u003eRounded inner chamber for easy cleaning\u003c\/li\u003e\n\u003cli\u003eAttractive door profile\u003c\/li\u003e\n\u003cli\u003eData logger for 8 Point (4+4) temperature\/humidity recording with the sensor, printer interface and software (Optional)\u003c\/li\u003e\n\u003cli\u003eOptional\n\u003cul\u003e\n\u003cli\u003eTouch screen display ( TFT ) with additional features(Details overleaf)\u003c\/li\u003e\n\u003cli\u003eValidation protocol with IQ, OQ, PQ Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eLCD DISPLAY\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e4 Inch attractive LCD display\u003c\/li\u003e\n\u003cli\u003eIntelligent Controller helps maintain the temperature in case of sensor failure\u003c\/li\u003e\n\u003cli\u003eBattery Backup for Temperature Controller\u003c\/li\u003e\n\u003cli\u003eAuto tuning of controller\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnosis for errors\u003c\/li\u003e\n\u003cli\u003eHistogram format of 24 hours temperature recording\u003c\/li\u003e\n\u003cli\u003ePower failure and resumption recorded with date and time\u003c\/li\u003e\n\u003cli\u003eSettable High \/ low alarm points\u003c\/li\u003e\n\u003cli\u003eMemory for storage of up to 1000 records\u003c\/li\u003e\n\u003cli\u003eCentronic interface to record Temperature, Date, \u0026amp; Time by attaching Dot Matrix printer with adjustable print interval\u003c\/li\u003e\n\u003cli\u003eThe alarm on equipment\/output for remote alarm\u003c\/li\u003e\n\u003cli\u003ePC communication through RS-485 with data acquisition software\u003c\/li\u003e\n\u003cli\u003eRemi “Datasoft”™ Data acquisition software complying to 21 CFR part 11 as per USFDA Guidelines (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eREMI ‘DATA SOFT’\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple level alphanumerical passwords with password aging\u003c\/li\u003e\n\u003cli\u003eSecured audit trail report\u003c\/li\u003e\n\u003cli\u003eAlarm report with mention of the alarm condition\u003c\/li\u003e\n\u003cli\u003eMean Kinetic Temperature able to be calculated for any days \u0026amp; alarm deviation report\u003c\/li\u003e\n\u003cli\u003eReports in graphical and tabular form\u003c\/li\u003e\n\u003cli\u003eData Stored in PC server with Lan connectivity and can be monitored on PC with password authentication\u003c\/li\u003e\n\u003cli\u003eMulti-chamber data acquisition on a single software\u003c\/li\u003e\n\u003cli\u003eCommunication through RS 485 \/ TCP IP\u003c\/li\u003e\n\u003cli\u003eGSM Mobile Alert for six Numbers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eOPTIONAL ACCESSORIES\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eTo be Ordered separately\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChamber illumination with the help of 2 Nos. fluorescent tubes\u003c\/li\u003e\n\u003cli\u003eChamber illumination with 2 Nos. ultraviolet lights\u003c\/li\u003e\n\u003cli\u003e24 hours Cyclic Timer for regulating illumination conditions\u003c\/li\u003e\n\u003cli\u003eData logger for 8 \/ 16 Point temperature \u0026amp; Humidity recording with sensors printer interface and software\u003c\/li\u003e\n\u003cli\u003eSoftware as per 21 CFR Part 11 requirements\u003c\/li\u003e\n\u003cli\u003ePLC Based Control System with HMI Touch Screen\u003c\/li\u003e\n\u003cli\u003eBiometrics Magnetic Door Access for Secured Door opening with software to maintain a log\u003c\/li\u003e\n\u003cli\u003eValidation (mapping) consists of one cycle for the temperature at any one set point for 24 hours on empty and loaded condition\u003c\/li\u003e\n\u003cli\u003eStandby Refrigeration System\u003c\/li\u003e\n\u003cli\u003eStandby Humidity System\u003c\/li\u003e\n\u003cli\u003eGSM alert through SIM card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoTable15Grid6Colorful\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eModel No.\u003cb\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eCHM-19\u003cb\u003e Plus\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInternal Volume (Liters)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e540\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eNumber of Shelves\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInternal Dimensions W x D x H (mm)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e660 x 655 x 1250\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eExternal Dimensions W x D x H (mm)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e800 x 1095 x 1820\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eTemperature Range \u0026amp; Accuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e10°C to 60°C, ± 1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eHumidity Range (Rh) \u0026amp; Accuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e40% to 95%, ± 3%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eTemperature \u0026amp; Humidity control\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMicroprocessor with Capacitance type sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e4″ LCD Screen, Large size Display for ease of reading\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003ePower Failure Alarm\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eVisual Alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eDoor Open Alarm\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAudio Visual Alarm in case door open for over one minute\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eTemperature \/ Humidity Variation Alarm\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eSet Humidity ± 3%, Set Temperature ± 1°C, Audio Visual Alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eIllumination\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e8 Watts Fluorescent Tube\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInternal Body Material\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eStainless Steel – 304 grade (Standard Models), Stainless Steel – 316 grade (GMP Models)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eExternal Body Material\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePowder Coated CRCA Steel (Standard Models), Stainless Steel – 304 grade (GMP Models)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInsulation\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e70 mm minimum for Body \u0026amp; 80 mm for Door, CFC free polyurethane foam\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eNoise Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eLess Than 65 db(A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eRecommended Voltage Stabilizer\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eVS-04\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cstyle\u003e\n    \/* Professional Clean Layout - Grey \u0026 #00a0e3 Theme *\/\n    .labend-chm19-container {\n        font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif;\n        color: #444;\n        max-width: 1100px;\n        margin: 0 auto;\n        line-height: 1.8;\n    }\n\n    .accent-top-v7 {\n        width: 150px;\n        height: 5px;\n        background-color: #00a0e3;\n        margin: 30px 0;\n    }\n\n    .product-info-text {\n        font-size: 16px;\n        text-align: justify;\n        margin-bottom: 25px;\n        color: #555;\n    }\n\n    .main-heading-v7 {\n        color: #00a0e3;\n        font-size: 24px;\n        font-weight: 400;\n        margin: 45px 0 20px 0;\n        padding-bottom: 5px;\n        border-bottom: 1px solid #eee;\n        text-transform: uppercase;\n    }\n\n    \/* Specifications Design - Alternating List *\/\n    .specs-list-v7 {\n        display: flex;\n        flex-wrap: wrap;\n        gap: 10px;\n        margin: 30px 0;\n    }\n\n    .spec-item-v7 {\n        flex: 1 1 45%;\n        padding: 12px 20px;\n        background: #f9f9f9;\n        border-left: 4px solid #00a0e3;\n        font-size: 15px;\n    }\n\n    .spec-item-v7 b {\n        color: #333;\n        display: inline-block;\n        width: 140px;\n    }\n\n    \/* FAQ Design - Simple Modern Cards *\/\n    .faq-wrapper-v7 {\n        margin: 35px 0;\n    }\n\n    .faq-box-v7 {\n        padding: 15px;\n        margin-bottom: 15px;\n        border: 1px solid #f0f0f0;\n        border-radius: 4px;\n    }\n\n    .faq-q-v7 {\n        color: #00a0e3;\n        font-weight: 600;\n        font-size: 16px;\n        margin-bottom: 5px;\n    }\n\n    .faq-a-v7 {\n        color: #666;\n        font-size: 15px;\n    }\n\n    \/* Modern Links Grid *\/\n    .links-section-v7 {\n        background: #f4f4f4;\n        padding: 40px;\n        margin: 50px 0;\n        border-radius: 8px;\n    }\n\n    .links-grid-v7 {\n        display: grid;\n        grid-template-columns: repeat(auto-fill, minmax(230px, 1fr));\n        gap: 12px;\n    }\n\n    .links-grid-v7 a {\n        background: #fff;\n        color: #00a0e3;\n        text-decoration: none;\n        font-size: 12px;\n        padding: 10px;\n        border: 1px solid #ddd;\n        text-align: center;\n        transition: 0.3s;\n    }\n\n    .links-grid-v7 a:hover {\n        background: #00a0e3;\n        color: #fff;\n        border-color: #00a0e3;\n    }\n\n    \/* Keywords Cloud *\/\n    .keywords-cloud-v7 {\n        font-size: 13px;\n        color: #888;\n        text-align: center;\n        padding: 30px;\n        border-top: 1px solid #eee;\n        line-height: 2.2;\n    }\n\n    \/* Target Footer *\/\n    .global-footer-v7 {\n        background: #333;\n        color: #00a0e3;\n        padding: 40px 20px;\n        text-align: center;\n        font-size: 11px;\n        letter-spacing: 1.5px;\n        text-transform: uppercase;\n        margin-top: 30px;\n    }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"labend-chm19-container\"\u003e\n    \u003cdiv class=\"accent-top-v7\"\u003e\u003c\/div\u003e\n\n    \u003cdiv class=\"product-info-text\"\u003e\n        The \u003cstrong\u003eRemi LCD Humidity Chamber (CHM-19 Plus)\u003c\/strong\u003e is an industrial-grade environmental control system featuring a massive 540-liter capacity. Designed for laboratories that manage high-volume samples, this model utilizes a high-performance microprocessor-based LCD controller for steady and accurate climatic conditions. It is engineered to provide long-term stability for samples that require specific humidity and temperature ranges, following ICH guidelines for pharmaceutical research. The large internal volume makes it one of the most efficient solutions for bulk testing in quality control departments.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"product-info-text\"\u003e\n        Built with high-quality SS 304 mirror-finish stainless steel internally, the CHM-19 Plus ensures maximum durability and corrosion resistance. The chamber is equipped with a high-accuracy electronic humidity sensor and a powerful forced-air circulation fan to maintain uniform conditions across all 8 adjustable shelves. Safety features include an audio-visual alarm for temperature deviations, a low-water level cutoff for the steam generator, and a non-volatile memory that stores up to 1000 records. Its robust construction and precise control system make it ideal for demanding laboratory environments worldwide.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"main-heading-v7\"\u003eTechnical Specifications\u003c\/div\u003e\n    \u003cdiv class=\"specs-list-v7\"\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eInternal Volume\u003c\/b\u003e 540 Liters\u003c\/div\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eDisplay Type\u003c\/b\u003e 4\" LCD Microprocessor\u003c\/div\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eTemp Range\u003c\/b\u003e 10°C to 60°C\u003c\/div\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eHumidity Range\u003c\/b\u003e 40% to 95% RH\u003c\/div\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eData Storage\u003c\/b\u003e 1000 Records (Internal)\u003c\/div\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eShelving\u003c\/b\u003e 8 Adjustable SS Shelves\u003c\/div\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eInternal Body\u003c\/b\u003e SS 304 Mirror Finish\u003c\/div\u003e\n        \u003cdiv class=\"spec-item-v7\"\u003e\n\u003cb\u003eExternal Body\u003c\/b\u003e Powder Coated CRCA Steel\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"main-heading-v7\"\u003eCommon Uses\u003c\/div\u003e\n    \u003cp class=\"product-info-text\"\u003e\n        This chamber is perfect for large-scale stability trials in the pharmaceutical industry, shelf-life testing of food and beverages, and environmental stress testing for large electronic components. It is also used in agricultural research for bulk seed testing, accelerated aging of cosmetic products, and long-term storage of biological samples under precise humidity control.\n    \u003c\/p\u003e\n\n    \u003cdiv class=\"main-heading-v7\"\u003eFrequently Asked Questions\u003c\/div\u003e\n    \u003cdiv class=\"faq-wrapper-v7\"\u003e\n        \u003cdiv class=\"faq-box-v7\"\u003e\n            \u003cdiv class=\"faq-q-v7\"\u003e1. Is the CHM-19 Plus suitable for ICH stability guidelines?\u003c\/div\u003e\n            \u003cdiv class=\"faq-a-v7\"\u003eYes, it is specifically designed to maintain the temperature and humidity tolerances required by ICH stability testing protocols.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"faq-box-v7\"\u003e\n            \u003cdiv class=\"faq-q-v7\"\u003e2. How many shelves come with the 540L model?\u003c\/div\u003e\n            \u003cdiv class=\"faq-a-v7\"\u003eThe CHM-19 Plus comes standard with 8 adjustable stainless steel shelves to maximize loading capacity.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"faq-box-v7\"\u003e\n            \u003cdiv class=\"faq-q-v7\"\u003e3. Does it have a data logging feature?\u003c\/div\u003e\n            \u003cdiv class=\"faq-a-v7\"\u003eYes, the microprocessor controller includes a data logger that can store up to 1000 time-stamped records in its memory.\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"faq-box-v7\"\u003e\n            \u003cdiv class=\"faq-q-v7\"\u003e4. Can I use this for accelerated aging tests?\u003c\/div\u003e\n            \u003cdiv class=\"faq-a-v7\"\u003eAbsolutely. It can maintain stable high-humidity and high-temperature conditions ideal for accelerated aging studies.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"main-heading-v7\"\u003eRelated Keywords\u003c\/div\u003e\n    \u003cdiv class=\"keywords-cloud-v7\"\u003e\n        Remi CHM-19 Plus LCD Humidity Chamber, 540 Liter Environmental Chamber, Large Capacity Stability Chamber India, Remi Electrotechnik Distributor, Labend Scientific Instruments, Industrial Humidity Chamber Price, Pharmaceutical Climatic Testing, ICH Stability Testing Equipment, Remi CHM Series Exporter, Large Volume Lab Incubator, Stainless Steel Humidity Chamber SS 304, Remi LCD Chamber Manual, Accelerated Aging Test Chamber, High Accuracy Environmental Control, Remi Lab Equipment Mumbai, Humidity Controlled Cabinet 540L, Pharmaceutical QA Tools, Climate Chamber for Food Testing, Remi Humidity Chamber Online, Bulk Stability Testing Chamber.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"main-heading-v7\"\u003eRelated Product Links\u003c\/div\u003e\n    \u003cdiv class=\"links-section-v7\"\u003e\n        \u003cdiv class=\"links-grid-v7\"\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/collections\/environmental-chambers-and-cabinets\"\u003eEnvironmental Cabinets\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-6-plus\"\u003eREMI LCD SC-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-6-plus\"\u003eREMI TFT SC-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-10-plus\"\u003eREMI LCD SC-10 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-10-plus\"\u003eREMI TFT SC-10 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-12-plus\"\u003eREMI LCD SC-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-12-plus\"\u003eREMI TFT SC-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-16-plus\"\u003eREMI LCD SC-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-16-plus\"\u003eREMI TFT SC-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-19-plus\"\u003eREMI LCD SC-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-19-plus\"\u003eREMI TFT SC-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-28-plus\"\u003eREMI LCD SC-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-28-plus\"\u003eREMI TFT SC-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-35-plus\"\u003eREMI LCD SC-35 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-35-plus\"\u003eREMI TFT SC-35 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-6-plus\"\u003eREMI LCD CHM-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-6-plus\"\u003eREMI TFT CHM-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-10-plus\"\u003eREMI TFT CHM-10 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-12-plus\"\u003eREMI LCD CHM-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-12-plus\"\u003eREMI TFT CHM-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-16-plus\"\u003eREMI LCD CHM-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-16-plus\"\u003eREMI TFT CHM-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-19-plus\"\u003eREMI LCD CHM-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-19-plus\"\u003eREMI TFT CHM-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-28-plus\"\u003eREMI LCD CHM-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-28-plus\"\u003eREMI TFT CHM-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-35-plus\"\u003eREMI LCD CHM-35 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-35-plus\"\u003eREMI TFT CHM-35 Plus\u003c\/a\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"global-footer-v7\"\u003e\n        TARGET COUNTRIES: INDIA | USA | UK | UAE | SAUDI ARABIA | CANADA | AUSTRALIA | SINGAPORE | GERMANY | MALAYSIA | FRANCE | BRAZIL | SOUTH AFRICA | JAPAN | SOUTH KOREA | RUSSIA | MEXICO | NETHERLANDS | TURKEY | EGYPT | VIETNAM | THAILAND | INDONESIA | NIGERIA | PHILIPPINES | QATAR | OMAN | SWITZERLAND | BELGIUM | POLAND | ITALY\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"Labend India","offers":[{"title":"Default Title","offer_id":46925920993538,"sku":"100","price":261180.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/3241\/7794\/files\/CHM-19Plus.jpg?v=1761570577","url":"https:\/\/www.labend.com\/products\/remi-lcd-chm-19-plus","provider":"Labend","version":"1.0","type":"link"}