{"product_id":"remi-lcd-chm-16-plus","title":"Remi LCD Humidity Chamber (CHM-16 Plus)","description":"\u003cbody\u003e\n\u003cp\u003eCHM-16 Plus - Remi LCD Humidity Chamber\u003c\/p\u003e\n\u003cdiv class=\"wpb_text_column wpb_content_element  wpb_animate_when_almost_visible wpb_right-to-left wpb_start_animation\"\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003cp\u003eREMI Humidity Chambers are designed for testing of electronic, electrical components, corrosion studies on mechanical parts, shelf-life studies on paints, varnishes, and cement at respective manufacturing facilities. These chambers control precise temperature and Humidity.\u003cbr\u003e\u003cspan\u003eThese chambers are available in standard \u0026amp; GMP versions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"wpb_text_column wpb_content_element  wpb_animate_when_almost_visible wpb_right-to-left wpb_start_animation\"\u003e\n\u003cdiv class=\"wpb_wrapper\"\u003e\n\u003ch4\u003eSALIENT FEATURES\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePrecise monitoring of temperature and humidity conditions\u003c\/li\u003e\n\u003cli\u003eTemperature range 10°C to 60°C, Humidity range 40% to 95% RH\u003c\/li\u003e\n\u003cli\u003eThe unique design of the thermal barrier for better energy efficiency\u003c\/li\u003e\n\u003cli\u003eMachine filled PUF insulation to eliminate void pockets\u003c\/li\u003e\n\u003cli\u003ePowerful fan motor for forced air circulation to maintain uniform conditions inside the chamber\u003c\/li\u003e\n\u003cli\u003eHeating by long-life SS tubular heaters\u003c\/li\u003e\n\u003cli\u003eHermetically sealed Compressor with CFC free refrigerant\u003c\/li\u003e\n\u003cli\u003eChamber calibration port on the side\u003c\/li\u003e\n\u003cli\u003eAdjustable trays\u003c\/li\u003e\n\u003cli\u003eOutput for remote alarm\u003c\/li\u003e\n\u003cli\u003eMicroprocessor controller with LCD display \u0026amp; capacitance type sensor\u003c\/li\u003e\n\u003cli\u003e4″ attractive LCD display for direct display of humidity \u0026amp; temperature\u003c\/li\u003e\n\u003cli\u003eAuto tuning of controller\u003c\/li\u003e\n\u003cli\u003eSettable High \/ low alarm points with date and time\u003c\/li\u003e\n\u003cli\u003eCentronic interface to record Temperature, Humidity, Date \u0026amp; Time by attaching Dot Matrix printer with adjustable print interval\u003c\/li\u003e\n\u003cli\u003eRemi “Datasoft”™ data acquisition software as per 21 CFR part 11 requirements (Optional)\u003c\/li\u003e\n\u003cli\u003ePower failure and resumption recorded with date and time\u003c\/li\u003e\n\u003cli\u003ePC communication through RS-485 with data acquisition software\u003c\/li\u003e\n\u003cli\u003eHigh-temperature safety cut off \u0026amp; alarms for high\/lowset parameters\u003c\/li\u003e\n\u003cli\u003eLow water level alarm and power cutoff of boiler tank heater\u003c\/li\u003e\n\u003cli\u003eOverload cut off relay for compressor\u003c\/li\u003e\n\u003cli\u003eRounded inner chamber for easy cleaning\u003c\/li\u003e\n\u003cli\u003eAttractive door profile\u003c\/li\u003e\n\u003cli\u003eData logger for 8 Point (4+4) temperature\/humidity recording with the sensor, printer interface and software (Optional)\u003c\/li\u003e\n\u003cli\u003eOptional\n\u003cul\u003e\n\u003cli\u003eTouch screen display ( TFT ) with additional features(Details overleaf)\u003c\/li\u003e\n\u003cli\u003eValidation protocol with IQ, OQ, PQ Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eLCD DISPLAY\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e4 Inch attractive LCD display\u003c\/li\u003e\n\u003cli\u003eIntelligent Controller helps maintain the temperature in case of sensor failure\u003c\/li\u003e\n\u003cli\u003eBattery Backup for Temperature Controller\u003c\/li\u003e\n\u003cli\u003eAuto tuning of controller\u003c\/li\u003e\n\u003cli\u003eSelf-Diagnosis for errors\u003c\/li\u003e\n\u003cli\u003eHistogram format of 24 hours temperature recording\u003c\/li\u003e\n\u003cli\u003ePower failure and resumption recorded with date and time\u003c\/li\u003e\n\u003cli\u003eSettable High \/ low alarm points\u003c\/li\u003e\n\u003cli\u003eMemory for storage of up to 1000 records\u003c\/li\u003e\n\u003cli\u003eCentronic interface to record Temperature, Date, \u0026amp; Time by attaching Dot Matrix printer with adjustable print interval\u003c\/li\u003e\n\u003cli\u003eThe alarm on equipment\/output for remote alarm\u003c\/li\u003e\n\u003cli\u003ePC communication through RS-485 with data acquisition software\u003c\/li\u003e\n\u003cli\u003eRemi “Datasoft”™ Data acquisition software complying to 21 CFR part 11 as per USFDA Guidelines (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eREMI ‘DATA SOFT’\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple level alphanumerical passwords with password aging\u003c\/li\u003e\n\u003cli\u003eSecured audit trail report\u003c\/li\u003e\n\u003cli\u003eAlarm report with mention of the alarm condition\u003c\/li\u003e\n\u003cli\u003eMean Kinetic Temperature able to be calculated for any days \u0026amp; alarm deviation report\u003c\/li\u003e\n\u003cli\u003eReports in graphical and tabular form\u003c\/li\u003e\n\u003cli\u003eData Stored in PC server with Lan connectivity and can be monitored on PC with password authentication\u003c\/li\u003e\n\u003cli\u003eMulti-chamber data acquisition on a single software\u003c\/li\u003e\n\u003cli\u003eCommunication through RS 485 \/ TCP IP\u003c\/li\u003e\n\u003cli\u003eGSM Mobile Alert for six Numbers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eOPTIONAL ACCESSORIES\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eTo be Ordered separately\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChamber illumination with the help of 2 Nos. fluorescent tubes\u003c\/li\u003e\n\u003cli\u003eChamber illumination with 2 Nos. ultraviolet lights\u003c\/li\u003e\n\u003cli\u003e24 hours Cyclic Timer for regulating illumination conditions\u003c\/li\u003e\n\u003cli\u003eData logger for 8 \/ 16 Point temperature \u0026amp; Humidity recording with sensors printer interface and software\u003c\/li\u003e\n\u003cli\u003eSoftware as per 21 CFR Part 11 requirements\u003c\/li\u003e\n\u003cli\u003ePLC Based Control System with HMI Touch Screen\u003c\/li\u003e\n\u003cli\u003eBiometrics Magnetic Door Access for Secured Door opening with software to maintain a log\u003c\/li\u003e\n\u003cli\u003eValidation (mapping) consists of one cycle for the temperature at any one set point for 24 hours on empty and loaded condition\u003c\/li\u003e\n\u003cli\u003eStandby Refrigeration System\u003c\/li\u003e\n\u003cli\u003eStandby Humidity System\u003c\/li\u003e\n\u003cli\u003eGSM alert through SIM card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoTable15Grid6Colorful\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eModel No.\u003cb\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cb\u003e\u003cspan\u003eCHM-\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e1\u003cb\u003e6 Plus\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInternal Volume (Liters)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e450\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eNumber of Shelves\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInternal Dimensions W x D x H (mm)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e660 x 655 x 1050\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eExternal Dimensions W x D x H (mm)\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e800 x 1095 x 1620\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eTemperature Range \u0026amp; Accuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e10°C to 60°C, ± 1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eHumidity Range (Rh) \u0026amp; Accuracy\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e40% to 95%, ± 3%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eTemperature \u0026amp; Humidity control\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMicroprocessor with Capacitance type sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e4″ LCD Screen, Large size Display for ease of reading\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003ePower Failure Alarm\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eVisual Alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eDoor Open Alarm\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAudio Visual Alarm in case door open for over one minute\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eTemperature \/ Humidity Variation Alarm\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eSet Humidity ± 3%, Set Temperature ± 1°C, Audio Visual Alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eIllumination\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e8 Watts Fluorescent Tube\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInternal Body Material\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eStainless Steel – 304 grade (Standard Models), Stainless Steel – 316 grade (GMP Models)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eExternal Body Material\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePowder Coated CRCA Steel (Standard Models), Stainless Steel – 304 grade (GMP Models)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eInsulation\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e70 mm minimum for Body \u0026amp; 80 mm for Door, CFC free polyurethane foam\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eNoise Level\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eLess Than 65 db(A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003eRecommended Voltage Stabilizer\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eVS-04\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cstyle\u003e\n    \/* Clean Modern Layout - Grey \u0026 #00a0e3 Theme *\/\n    .remi-chm16-container {\n        font-family: 'Segoe UI', Arial, sans-serif;\n        color: #444;\n        max-width: 1150px;\n        margin: 0 auto;\n        line-height: 1.8;\n    }\n\n    \/* Abstract Top Line *\/\n    .top-design-v5 {\n        width: 100%;\n        height: 1px;\n        background: #eee;\n        margin: 35px 0;\n        position: relative;\n    }\n    .top-design-v5::before {\n        content: '';\n        position: absolute;\n        width: 140px;\n        height: 5px;\n        background: #00a0e3;\n        top: -2px;\n        left: 0;\n    }\n\n    .info-block-v5 {\n        font-size: 16px;\n        text-align: justify;\n        margin-bottom: 25px;\n        color: #555;\n    }\n\n    .heading-v5 {\n        color: #00a0e3;\n        font-weight: 300;\n        font-size: 26px;\n        margin: 45px 0 20px 0;\n        letter-spacing: 0.8px;\n        text-transform: uppercase;\n    }\n\n    \/* Specifications - Minimal Pillar Style *\/\n    .specs-matrix-v5 {\n        display: grid;\n        grid-template-columns: repeat(auto-fill, minmax(270px, 1fr));\n        gap: 15px;\n        margin: 30px 0;\n    }\n    .spec-unit-v5 {\n        padding: 15px 20px;\n        border-left: 2px solid #00a0e3;\n        background: #f9f9f9;\n        transition: 0.3s;\n    }\n    .spec-unit-v5:hover {\n        background: #f0f8ff;\n    }\n    .spec-unit-v5 small {\n        display: block;\n        color: #00a0e3;\n        font-size: 11px;\n        text-transform: uppercase;\n        font-weight: 700;\n    }\n\n    \/* FAQ - Clean Split Design *\/\n    .faq-grid-v5 {\n        display: grid;\n        grid-template-columns: 1fr 1fr;\n        gap: 30px;\n        margin: 40px 0;\n    }\n    .faq-item-v5 {\n        padding: 15px;\n        border-bottom: 1px solid #f0f0f0;\n    }\n    .faq-item-v5 strong {\n        color: #00a0e3;\n        display: block;\n        font-size: 16px;\n        margin-bottom: 6px;\n    }\n\n    \/* Links Matrix - Modern Tag Style *\/\n    .links-matrix-v5 {\n        background: #f4f4f4;\n        padding: 45px;\n        margin: 55px 0;\n        border-top: 3px solid #00a0e3;\n    }\n    .link-columns-v5 {\n        column-count: 3;\n        column-gap: 25px;\n    }\n    .link-columns-v5 a {\n        display: block;\n        color: #666;\n        text-decoration: none;\n        font-size: 13px;\n        margin-bottom: 12px;\n        transition: 0.2s;\n    }\n    .link-columns-v5 a:hover {\n        color: #00a0e3;\n        padding-left: 5px;\n    }\n\n    \/* Keyword Strategy Section *\/\n    .keyword-cloud-v5 {\n        font-size: 13px;\n        color: #888;\n        padding: 35px;\n        text-align: center;\n        background: #fff;\n        border: 1px solid #eee;\n        line-height: 2.5;\n        margin-top: 50px;\n    }\n\n    \/* Global Footer Targets *\/\n    .export-targets-footer {\n        background: #333;\n        color: #00a0e3;\n        padding: 45px 20px;\n        text-align: center;\n        font-size: 10px;\n        letter-spacing: 2px;\n        text-transform: uppercase;\n        margin-top: 40px;\n    }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"remi-chm16-container\"\u003e\n    \u003cdiv class=\"top-design-v5\"\u003e\u003c\/div\u003e\n\n    \u003cdiv class=\"info-block-v5\"\u003e\n        The \u003cstrong\u003eRemi LCD Humidity Chamber (CHM-16 Plus)\u003c\/strong\u003e is a large-scale environmental testing solution with a massive 450-liter internal capacity. This professional-grade chamber is designed for industrial and pharmaceutical laboratories that require stable climatic conditions for high-volume sample testing. Equipped with a microprocessor-based LCD controller, it provides precise regulation of temperature and humidity, ensuring accuracy in long-term stability studies. The CHM-16 Plus is engineered to maintain uniform environmental parameters, making it a reliable choice for shelf-life testing and quality assurance across various industries.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"info-block-v5\"\u003e\n        Constructed for durability and consistent performance, the chamber features a high-grade Stainless Steel (SS 304) interior with a mirror-finish to resist corrosion in high-humidity environments. The outer body is made of heavy-duty CRCA steel with an epoxy powder coating for long-lasting lab use. Its advanced forced-air circulation system eliminates thermal variations, ensuring every sample receives identical exposure. With safety features like high-temperature cut-offs and low-water alarms, the CHM-16 Plus protects sensitive biological materials, chemicals, and electronic components during rigorous testing cycles.\n    \u003c\/div\u003e\n\n    \u003ch3 class=\"heading-v5\"\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cdiv class=\"specs-matrix-v5\"\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eInternal Capacity\u003c\/small\u003e450 Liters\u003c\/div\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eController Type\u003c\/small\u003eMicroprocessor LCD Display\u003c\/div\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eTemperature Range\u003c\/small\u003e10.0°C to 60.0°C\u003c\/div\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eHumidity Range\u003c\/small\u003e40% to 95% RH\u003c\/div\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eUniformity\u003c\/small\u003e± 1.0°C \/ ± 3% RH\u003c\/div\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eInternal Material\u003c\/small\u003eStainless Steel (SS 304)\u003c\/div\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eStorage System\u003c\/small\u003e6 Adjustable SS Shelves\u003c\/div\u003e\n        \u003cdiv class=\"spec-unit-v5\"\u003e\n\u003csmall\u003eData Management\u003c\/small\u003eInternal Memory (1000 Records)\u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003ch3 class=\"heading-v5\"\u003eIndustrial Applications\u003c\/h3\u003e\n    \u003cp class=\"info-block-v5\"\u003e\n        The CHM-16 Plus is ideal for pharmaceutical stability trials following ICH guidelines, large-batch cosmetics testing, and quality control of electronic components under humidity stress. It is also extensively used in agricultural science for plant growth studies, microbiological incubation, and the shelf-life validation of food and beverage products in high-volume production facilities.\n    \u003c\/p\u003e\n\n    \u003ch3 class=\"heading-v5\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n    \u003cdiv class=\"faq-grid-v5\"\u003e\n        \u003cdiv class=\"faq-item-v5\"\u003e\n            \u003cstrong\u003e1. What is the benefit of the 450L capacity?\u003c\/strong\u003e\n            The large volume allows for the testing of bulk samples or larger individual components, reducing the need for multiple smaller chambers.\n        \u003c\/div\u003e\n        \u003cdiv class=\"faq-item-v5\"\u003e\n            \u003cstrong\u003e2. How does the chamber handle water for humidity?\u003c\/strong\u003e\n            It features an integrated steam generator with low-water safety sensors to prevent heating without water, ensuring system longevity.\n        \u003c\/div\u003e\n        \u003cdiv class=\"faq-item-v5\"\u003e\n            \u003cstrong\u003e3. Is the data logging secure?\u003c\/strong\u003e\n            The microprocessor controller stores up to 1000 time-stamped records in non-volatile memory, protecting data during power outages.\n        \u003c\/div\u003e\n        \u003cdiv class=\"faq-item-v5\"\u003e\n            \u003cstrong\u003e4. Can it handle accelerated aging tests?\u003c\/strong\u003e\n            Yes, the precision temperature and humidity range are specifically designed for both long-term and accelerated stability trials.\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003ch3 class=\"heading-v5\"\u003eRelated Keywords\u003c\/h3\u003e\n    \u003cdiv class=\"keyword-cloud-v5\"\u003e\n        Remi LCD Humidity Chamber CHM-16 Plus, 450 Liter Environmental Chamber, Large Capacity Stability Chamber India, Remi Electrotechnik Distributor, Labend Scientific Instruments, Pharmaceutical Humidity Testing Tools, ICH Guideline Stability Cabinet, Remi CHM Series Price, Industrial Climatic Chamber, High Volume Environmental Test, SS 304 Humidity Chamber Exporter, Remi CHM-16 Plus Specification, Constant Temperature Humidity Chamber Online, Scientific Lab Equipment Mumbai, Pharma QA QC Tools, Humidity Controlled Incubator 450L, Accelerated Aging Chamber price, Remi Lab Instruments Dealer, Constant Climate Chamber for Labs, Stability Testing Equipment Manufacturer.\n    \u003c\/div\u003e\n\n    \u003ch3 class=\"heading-v5\"\u003eProduct Navigation\u003c\/h3\u003e\n    \u003cdiv class=\"links-matrix-v5\"\u003e\n        \u003cdiv class=\"link-columns-v5\"\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/collections\/environmental-chambers-and-cabinets\"\u003eAll Collections\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-6-plus\"\u003eREMI LCD SC-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-6-plus\"\u003eREMI TFT SC-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-10-plus\"\u003eREMI LCD SC-10 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-10-plus\"\u003eREMI TFT SC-10 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-12-plus\"\u003eREMI LCD SC-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-12-plus\"\u003eREMI TFT SC-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-16-plus\"\u003eREMI LCD SC-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-16-plus\"\u003eREMI TFT SC-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-19-plus\"\u003eREMI LCD SC-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-19-plus\"\u003eREMI TFT SC-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-28-plus\"\u003eREMI LCD SC-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-28-plus\"\u003eREMI TFT SC-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-sc-35-plus\"\u003eREMI LCD SC-35 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-sc-35-plus\"\u003eREMI TFT SC-35 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-6-plus\"\u003eREMI LCD CHM-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-6-plus\"\u003eREMI TFT CHM-6 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-10-plus\"\u003eREMI TFT CHM-10 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-12-plus\"\u003eREMI LCD CHM-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-12-plus\"\u003eREMI TFT CHM-12 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-16-plus\"\u003eREMI LCD CHM-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-16-plus\"\u003eREMI TFT CHM-16 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-19-plus\"\u003eREMI LCD CHM-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-19-plus\"\u003eREMI TFT CHM-19 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-28-plus\"\u003eREMI LCD CHM-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-28-plus\"\u003eREMI TFT CHM-28 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-lcd-chm-35-plus\"\u003eREMI LCD CHM-35 Plus\u003c\/a\u003e\n            \u003ca href=\"https:\/\/www.labend.com\/products\/remi-tft-chm-35-plus\"\u003eREMI TFT CHM-35 Plus\u003c\/a\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"export-targets-footer\"\u003e\n        GLOBAL EXPORT REGIONS: INDIA | USA | UK | UAE | SAUDI ARABIA | CANADA | AUSTRALIA | SINGAPORE | GERMANY | MALAYSIA | FRANCE | BRAZIL | SOUTH AFRICA | JAPAN | SOUTH KOREA | RUSSIA | MEXICO | NETHERLANDS | TURKEY | EGYPT | VIETNAM | THAILAND | INDONESIA | NIGERIA | PHILIPPINES | QATAR | OMAN | SWITZERLAND | BELGIUM | POLAND | ITALY | SPAIN | SWEDEN\n    \u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\n\u003c\/div\u003e\n\u003c\/body\u003e","brand":"Labend India","offers":[{"title":"Default Title","offer_id":46925921059074,"sku":"100","price":250210.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/3241\/7794\/files\/CHM-16Plus.jpg?v=1761570579","url":"https:\/\/www.labend.com\/products\/remi-lcd-chm-16-plus","provider":"Labend","version":"1.0","type":"link"}